13 – 24-Hour Fire Zone 
A 24-Hour Fire Zone (Contact ID Event Code 110) is 
always ready to activate the dialer, horn speaker, 
bell, and strobe, whether the system is armed or 
disarmed. A distinct fire sound is emitted through the 
horn speaker to indicate this type of alarm. This fire 
sound is completely different from the burglary 
sound. A 24-Hour Fire zone does not send a Restore 
Report until the zone is restored. 
14 – Chime Zone 
A Chime Zone is not a burglary zone. It can never 
sound the sirens or activate the dialer. Its purpose is 
to map the zone to a programmable output to 
indicate if the zone is sealed or unsealed. Refer to 
Output Event Type 4,5 Global Chime on page 75.   
Chime zones require EOL resistors and are 
registered at a remote codepad. These zones do not 
affect the operation of forced arming. 
15 –Zone Not Used 
If a zone is not used, program the zone type location 
to 15. An EOL resistor is not required if this zone 
type is used. This zone type never sounds the sirens 
or activates the dialer.  
14.3.3 
Zone Pulse Count 
Zone pulse count is the number of times a zone must 
be activated before the zone registers an alarm. The 
number can vary from 0 to 15. The zone pulse count 
value is relative to the time frame (that is, the number 
of pulses that must be present during a particular 
time frame). Refer to Section 14.3.4 Zone Pulse Count 
Time
 for time frame settings. 
 
A zone that is programmed with a pulse 
count activates an alarm when it is 
continuously unsealed for 10 sec. A 24-
Hour Fire Zone programmed with a pulse 
count activates an alarm when it is 
continuously unsealed for 30 sec. 
Zone Pulse Count Handover 
Zone pulse count handover operates only with Zone 
Pulse Count Time options 8 to 15. Refer to Section 
14.3.4 Zone Pulse Count Time
 for more information. 
Any zone that registers one activate pulse 
automatically increments any other zone pulse count 
that already registered at least one activate pulse 
during its respective time. To enable this feature, 
select Option 4 in Location 494 (refer to Section 18.3 
System Options 3 
on page 81). 
 
24-Hour Zones will receive all handover 
pulses from other zones. 24-Hour Zones 
cannot handover pulses to other zones. 
14.3.4 
Zone Pulse Count Time 
Zone pulse count time is the time frame or period 
over which the programmed number of pulses must 
register to activate an alarm. 
Table 49:  Zone Pulse Count Times 
 
20 ms Loop Response  
150 ms Loop Response  
Option 
Time (sec) 
Option 
Time (sec) 
0 0.5 
 
8 20 
 
1  
30  
2  
10 
40  
3  
11 
50  
4  
12 
60  
5  
13 
90  
6 10 
 
14 
120 
 
7 15 
 
15 
200 
 
For zone pulse count time, options 0 to 7 have a zone 
loop response time of 20 ms and options 8 to 15 have 
a zone loop response time of 150 ms. Loop response 
time is the length of time a zone must be unsealed 
before it can register as a valid pulse. 
Inertia sensors should use options 0 to 7 and PIR 
detectors should use options 8 to 15. 
 
24-Hour Zones can receive any handover 
pulses from other zones. 24-Hour Zones 
cannot hand over pulses to other zones. 
14.3.5 
Zone Options 1 
This location has four programming options. You can 
select any combination of the options by 
programming a single value. Calculate this value by 
adding the option bit numbers together. Refer to 
Section 7.3 Programming Option Bits on page 36 for 
more information. 
Table 50:  Zone Options 1 
 
Option 
Description 
Lockout siren/lockout dialer 
Delay Alarm reporting 
4 Silent 
Alarm 
8 Sensor 
watch 
1 – Lockout Siren and Lockout Dialer 
Lockout refers to one activation per arming cycle 
(that is, a zone programmed for Lockout can activate 
the sirens or dialer only once). 
The next time the system is armed, the zone can 
activate the sirens and dialer once more. Restore 
signals are sent when the system is disarmed.