Barco CRT Television MSWU-81E User Manual

Page of 85
MSWU-81E  07/08/2013  
64
14.Lamp and Filter Maintenance
14. MAINTENANCE
14.1  Lamp Replacement
The lifecycle of ordinary projection lamp typically lasts for 2500 hours before requiring replacement (different lamp 
configurations will affect lamp life). From the OSD Menu, you can go to " 
 ".  to check how 
long a lamp has been used. You should also replace the lamp when the projected image gets noticeably darker. Contact your 
local dealer to purchase new certified lamps for your projector.
W
ARNING: This procedure may only be performed by qualified technical service personnel.
How to replace the projector lamp
W
ARNING: Switch off the projector and unplug the power cord before starting the procedure.
Keep all flammable items away from lamp
Never to remodel or disassembly on lamp housing
Lamp contains mercury. If lamp bursts during operation. Keep yourself in sufficiently ventilate area in order 
to avoid inhaling mercury.
1.  Turn off the projector and unplug the power cord. Let the projector cool for approximately 60 minutes before removing 
the lamp module for replacement.
 When you turn off the projector, the lamp inside the projector will still be very hot (approximately 200 ~ 
300°C). If you attempt to replace the lamp without allowing the projector to cool, you could risk scalding 
yourself. This is why you should wait for no less than 60 minutes for the lamp to cool down in order to 
perform the replacement safely.
2.  Loosen the Projector right side cover. 
 
 
3.  Loosen the lamp cover.