14.Lamp and Filter Maintenance
8.  Reconnect power to the projector and reset the lamp usage timer. Refer to 
 and 
 While starting up the projector, the electronics  detect if a lamp is installed.  If no lamp is installed, it is not 
possible to start up the projector.
14.2  Replace the filter (for inlet Ventilation)
Make sure to replace the filter when it is required to keep the air intake clear of dust, and prevent possible over temperature 
issue of the projector due to the clog of filter.
 
C
AUTION: The high density filter must be replaced on a regular basis, depending on the environment 
condi- tions of the projector.  Suggest to replace filter every 500 hours runtime.
W
ARNING: Switch off the projector and unplug the power cord before starting the procedure.
 
C
AUTION: Never use the projector with removed filters !
Necessary parts
New filter (available kit : R9899730, contains 2 high density filters)
 
C
AUTION: Never clean the filter Always replace with a new one.
How to change the filter
1.  Loosen the five screws on the projector left side cover.