Yamaha PJP-100H Owner's Manual

Page of 59
48
Troubleshooting
Q3: Call is impossible
Problem
Cause
Remedy
A call cannot be originated.
An inappropriate IP address is entered.
Check the IP address of the other unit and 
enter the correct IP address.
The IP address of the other unit has been 
changed.
Check the IP address of the other unit and 
enter the correct IP address.
The communication is blocked by a firewall.
Call by designating the IP address cannot 
cross a firewall. If you want to change the 
calling method to the SIP call, consult your 
system administrator.
A network fault occurred.
Wait until the fault is released.
Consult your system administrator.
The connection mode settings of this unit and 
the other unit are different.
A unit in the mesh connection mode cannot 
communicate with a unit in a cascade 
connection mode. Set the two units to the 
same connection mode (page 27).
The IP/SIP settings of this unit and the other 
unit are different.
A unit using the SIP address cannot 
communicate with a unit using the IP 
address. Enable or disable the SIP server 
operation as required so that both units use 
the same type of address (page 27).
The SIP address in the address book is 
incorrect.
Register the correct SIP address (page 35).
The SIP server is not running.
Consult your system administrator.
The SIP address of the other unit is not 
registered in the SIP server.
Consult your system administrator.
A call cannot be received.
An incorrect IP address is entered on the 
other unit.
Enter the correct IP address on the other unit.
The communication is blocked by a firewall.
Call by designating the IP address cannot 
cross a firewall. If you want to change the 
calling method to the SIP call, consult your 
system administrator.
A network fault occurred.
Wait until the fault is released.
Consult your system administrator.
01EN_00_PJP-100H_UCGB.book  Page 48  Wednesday, August 23, 2006  3:04 PM