Yamaha PJP-100H Owner's Manual

Page of 59
49
Troubleshooting
ADDITIONAL 
INF
O
RMA
T
IO
N
English
Problem
Cause
Remedy
A call cannot be received.
The connection mode settings of this unit and 
the other unit are different.
A unit in the mesh connection mode cannot 
communicate with a unit in a cascade 
connection mode. Set the two units to the 
same connection mode (page 27).
The IP/SIP settings of this unit and the other 
unit are different.
A unit using the SIP address cannot 
communicate with a unit using the IP 
address. Enable or disable the SIP server 
operation as required so that both units use 
the same type of address (page 27).
The SIP server is not running.
Consult your system administrator.
The audio from the other unit cannot 
be heard.
The microphones are muted on the other 
unit.
Cancel mute on the other unit.
The audio is interrupted.
The required bandwidth is not reserved.
Check that the bandwidth required for 
communication is reserved (page 8).
A network fault occurred.
Wait until the fault is released.
Consult your system administrator.
The LAN cable is not connected properly.
Check that the LAN cable is connected 
firmly.
Q4: Other problems
Problem
Cause
Remedy
The audio output is delayed.
The required bandwidth is not reserved.
Check that the bandwidth required for 
communication is reserved (page 8).
The unit generates feedback noises.
The unit is located against a wall.
Locate the unit at a certain distance from a 
wall.
An object is placed near this unit.
Avoid placing an object in front of the 
microphones.
This unit is used in a room with high 
reverberation.
Place objects with high sound absorbance in 
the room by avoiding the positions in front of 
the microphones.
Avoid talking at a loud voice to reduce 
reverberations.
The password is forgotten.
Reset this unit to restore the factory settings 
(page 50).
01EN_00_PJP-100H_UCGB.book  Page 49  Wednesday, August 23, 2006  3:04 PM