ZyXEL Communications Plumbing Product metrogigabit switch User Manual

Page of 448
 Chapter 31 Error Diable
MGS3700-12C User’s Guide
313
The following table describes the labels in this screen.
31.5  Error-Disable Detect Configuration
Use this screen to have the Switch detect whether the control packets exceed the 
rate limit configured for a port and configure the action to take once the limit is 
exceeded. Click the Click Here link next to Errdisable Detect link in the 
Advanced Application > Errdisable screen to display the screen as shown.
Figure 158   Advanced Application > Errdisable > Errdisable Detect
Table 99   Advanced Application > Errdisable > CPU protection
LABEL
DESCRIPTION
Reason
Select which type of packets that you want to configure here.
Port
This field displays the port number.
*
Use this row to make the setting the same for all ports. Use this row first 
and then make adjustments to each port if necessary. 
Note: Changes in this row are copied to all the ports as soon as you 
make them.
Rate Limit 
(pkt/s)
Enter a number from 0 to 256 to specify how many control packets this 
port can receive or transmit per second.
0 means no rate limit.
You can configure the action that the Switch takes when the limit is 
exceeded. See 
 for detailed information.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The 
Switch loses these changes if it is turned off or loses power, so use the 
Save link on the top navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.