VXi Computer Hardware VX1410A User Manual

Page of 360
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
3–31
STATus Subsystem
This section describes each command and query in the STATus subsystem. The
STATus subsystem controls the parameters shown in Figure 3–7.
STATus
OPERation
PRESet QUEStionable QUEue
SCONdition
BLOWer
FILTer
TEMPerature VOLTage
SEVent
VXIMonitor
POWer
CURRent
INTerrupt
VXITrigger
S2CONdition
S2EVent
Figure 3–7: STATus subsystem hierarchy
Use the STATus subsystem to monitor the status of the voltages, currents, power,
temperatures, fans, and the VXI Monitor.
The differences between the Event Registers and the Condition Register are as
follows:
H Reading the Event Register is destructive. Contents are reset to zero until an
event occurs. If the triggering event disappears, the corresponding event bit
remains set until the register is read or *RST (IEEE command) is performed.
H Reading the Condition Register is not destructive. The Condition Register
gives a real-time account of the status.
The Enable Register does not affect the related Event or Condition Registers. For
example, the Enable Register for the current sense
(“STAT:QUES:CURR:ENABLE?”) does not effect which bits are set in the
Condition Register (“STAT:QUES:CURR:COND?”). The Enable Register does
affect which bits will cause the current bit to be set in the questionable Event
Register (”STAT:QUES?”) or the questionable condition register
(“STAT:QUES:COND?”).
Examples:
1. Read the amperage draw used by the +5 Volt supply:
STAT:QUES:CURR:LEV? P5
The system response: 17.5