Utica Boilers CuB Series Installation Instruction

Page of 4
DOMESTIC HOT WATER SENSOR KIT
 
Figure 5 - Low Voltage Terminal Strip, CHB-130 
Shown
Figure 6 - Low Voltage Terminal Strip Removed from 
Boiler, CHB -130 Shown
Low Voltage 
Terminal Strip
Low Voltage 
Terminal Strip 
Removed
Figure 6
Temperature Deg F
Resistance in Ohms
32
32505
60
15689
70
11935
77
10000
100
8060
110
4732
120
3748
130
3104