Unibrain 780 User Manual

Page of 72
Unibrain Fire-i 580/780/785/980 Operation Manual 
 
Page 38 
 
 
 
 
3.14.1.  Strobe Delay / Duration Table   
The table shows the strobe index by increment step through the strobe delay time and the strobe duration time. The 
Increment Step is different according to strobe index. 
 
Strobe Delay Table 
Strobe Index(Y) 
Increment Step 
Strobe Delay Time : T 
Delay Time 
Range 
1us 
 
0us 
0us 
1us 
1us 
2us 
2us 
3~250 
T=Y us 
3us~250us 
251~3900 
T=Y us 
251us~3900us 
 
Strobe Duration Table 
Strobe Index(Y) 
Increment Step 
Strobe Duration Time : T 
Duration Time 
Range 
N.A 
N.A
 
N.A 
N.A 
N.A
 
N.A 
1us 
2us 
2us 
3~250 
1us 
T=Y us 
3us~250us 
251~489 
250us 
T=(Y-250)*250us+250us 
500us~60ms 
 
 
Delay Index(Y) 
Strobe Delay Time 
 
Duration Index (Y) 
Strobe Duration Time 
0us 
N.A
 
1us 
N.A
 
2us 
2us 
10 
10us 
10 
10us 
100 
100us 
100 
100us 
200 
200us 
250 
250us 
300 
300us 
253 
1ms 
500 
500us 
257 
2ms 
800 
800us 
269 
5ms 
1000 
1000us 
289 
10ms 
2000 
2000us 
329 
20ms 
3000 
3000us 
449 
50ms 
3900 
3900us 
489 
60ms