where:
For example, enter:
F100 G 206.54.0.17<CR>
XLi responds:
OK<CR><LF>
RESETING THE UNIT<CR><LF>
PLEASE WAIT…<CR><LF>
To obtain the Default Gateway of the unit Standard network port, enter:
F100 G<CR>
The XLi responds:
F100 G <nnn.nnn.nnn.nnn><CR><LF>
where “<nnn.nnn.nnn.nnn>” is the dotted decimal address notation.
An example of the response is:
F100 G:206.54.0.1<CR><LF>
F100 IC – Network Port Settings
Use function F100 IC to review the entire configuration of the standard network port, enter:
F100<S>IC<CR>
An example of the response is:
F100 IP:206.54.0.21 SM:255.255.255.240 G:206.54.0.17<CR><LF>
F100 BASET – 10/100 BASE- T
The BASET command displays the data rate of the Ethernet port. On the current version of the Main 
CPU card (87-8000) running the current system software version, the user also has the option of 
F
=  ASCII character F
100
= unit 
function 
number
<S>
= space
IP
= specify 
IP 
command
<nnn.nnn.nnn.nnn>
=  dotted decimal address (0 to 255)
<CR>
=  input line terminator