Symmetricom 1000 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
114  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Sample Command
ED-SYNC::PRS:TS1000::PRIORITY=2;
ED-SYNC::INP1:TS1000::PRIORITY=2;
ED-SYNC::INP2:TS1000::PRIORITY=2;
These commands set the PRIORITY for each input to the same value; if you also 
provision the QLEVEL to the same value, then you set up a non-revertive switching 
strategy.
Autonomous Message
TP-SSU 03-10-24 10:56:00
A 1184 REPT EVT
“PRS,EQPT:NA,PRIORITY,NSA,03-10-24 10-56-00:\"PRIORITY 
HAS CHANGED,2\””
;
Manually Selecting the Reference
Use the ED-SYNC command to manually select the reference. To select the 
reference, you must first set the REFMODE keyword to FORCED, as described in 
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::SYS:TS1000::INPREF=PRS;
This command forces the signal on the PRS input to be the reference signal. The 
REFMODE keyword must be set to FORCED for this command to take effect.
Autonomous Message
TP-SSU 03-10-24 10:58:30
A 1185 REPT EVT
“SYS,EQPT:NA,INPREF,NSA,03-10-24 10-58-30:\”SYSTEM 
REFERENCE INPUT HAS CHANGED, PRS\””
;
<aid>
<keyword>
<value>
Description
Default value
SYS
INPREF
GPS | PRS | INP1 | 
INP2
Sets the specified 
input to be the 
system reference
PRS