Symmetricom 1000 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
Provisioning Retimer Parameters
120  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Sample Command
ED-SYNC::OUTA:TS1000::FRMTYPE=CAS;
This command provisions output group A to an E1, CAS framing format.
Autonomous Message
TP-SSU 03-10-24 11:11:18
A 1190 REPT EVT
“OUTA,EQPT:NA,FRMTYPE,NSA,03-10-24 11-11-18:\"OUTPUT 
FRAMING TYPE HAS CHANGED,CAS\””
;
Provisioning Retimer Parameters
You use several TL1 commands to provision the E1 and T1 Retimers available for 
the TimeProvider. The ED-EQPT command with the RTMSTATE keyword allows 
you to enable and disable Retimer modules and individual ports; the SLIPCLR 
keyword allows you to clear a Slip alarm. The ED-SYNC command with the 
RTMLBO keyword allows you to set the line build-out length; the FREEFLT and 
HOLDFLT keywords allow you to enable or disable the cut-through mode when the 
clock enters Free-run or Holdover mode.
Enabling and Disabling the Retimers
Use the ED-EQPT command to enable or disable the specified Retimer group. 
Individual channels cannot be enabled or disabled.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::RTMA:TS1000::RTMSTATE=DISABLE;
This command disables the Retimer in group A and turns off both ports.
<aid>
<keyword>
<value>
Description
Default value
RTMg
g = A | B | C | D
RTMSTATE
ENABLE
Enable the specified 
Retimer group
ENABLE
DISABLE
Disable the specified 
Retimer group