Symmetricom 1000 User Manual

Page of 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 121
Chapter 4 Provisioning the TimeProvider
Provisioning Retimer Parameters
Autonomous Message
TP-SSU 03-10-24 11-09-12
A 1189 REPT EVT
“OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT 
GROUP STATE HAS CHANGED,DISABLE\””
;
Provisioning the LBO
Use the ED-SYNC command to set the line build-out (LBO) for each port (1 or 2) on 
the Retimer module.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::RTMA-1:TS1000::RTMLBO=2;
This command sets the line build-out length for port 1 in Retimer group A to 266 to 
399 ft (80 to 121 m).
Autonomous Message
TP-SSU 03-10-24 11-09-12
A 1189 REPT EVT
“RTMA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"LBO HAS 
CHANGED,2\””
;
<aid>
<keyword>
<value>
Description
Default value
RTMg[-p]
g = A | B | C | D 
p= 1 | 2
Note: The RTM-
LBO parameter is 
valid only for T1 
signals; for the 
E1 Retimer, the 
IPNV (Invalid 
Parameter) 
DENY code is 
returned.
RTMLBO
0
Sets the line build-out 
length to 0 to 133 ft 
(0 to 40 m)
0
1
Sets the line build-out 
length to 133 to 266 ft
(40 to 81 m)
2
Sets the line build-out 
length to 266 to 399 ft
(80 to 121 m)
3
Sets the line build-out 
length to 399 to 533 ft
(121 to 162 m)
4
Sets the line build-out 
length to 533 to 650 ft
(162 to 198 m)