Symmetricom 1000 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
92
 TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Setting the Handshaking (Flow) Mode
Use the ED-EQPT command to provision the handshaking mode on the local Craft 
or Remote port to None, Hardware, Software, or Hardware/Software.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::COML:TS1000::FLOW=HW;
Normal Response
TIMEPROVIDER 03-10-24 10:12:33
M
TS1000 COMPLD
;
Setting the Echo Mode
Use the ED-EQPT command to provision the echo mode on the local Craft or 
Remote port to On or Off. When set to ENABLE, characters you type at the 
keyboard also appear on the monitor. If one keystroke generates two characters on 
the monitor, set this parameter to DISABLE.
You can also use ED-EQPT to echo the <tid> in the response from the TimeProvider. 
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::COML:TS1000::ECHO=ENABLE;
Normal Response
TIMEPROVIDER 03-10-24 10:15:04
M
TS1000 COMPLD
;
<aid>
<keyword>
<value>
Description
Default value
COMp
p = L | R
FLOW 
NONE | SW | 
HW | SWHW
Flow control
NONE
<aid>
<keyword>
<value>
Description
Default value
COMp
p = L | R
ECHO 
ENABLE | DISABLE
Input echo
DISABLE
TIDQUIET
ENABLE | DISABLE
Enables or disables the 
echo of the <tid>. This 
is a session setting.
DISABLE