SimpleTech ZeusIOPS User Manual

Page of 84
32
Zeus
IOPS
 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0
-D
RIVE
 P
RESENT
This signal is connected to the ground plane of the drive. The backplane can use this signal to detect 
the presence of the drive.
D
EV
_C
TRL
_C
ODE
_
X
The DEV_CTRL_CODE_2 through DEV_CTRL_CODE_0 signals provide a binary code to the drive 
to control functions such as FC link rate, Power Failure Warning (PFW) and Hard Reset. The control 
function is either identified by a code or a sequence of codes on the DEV_CTRL_CODE signals. 
Table 9 lists the functions and the associated codes that use a decode value on the 
DEV_CTRL_CODE signals.
The Hard Reset function uses a sequence of values on the DEV_CTRL_CODE signals. The 
sequence is 5, 1, 3, 2, 3, 1 and 5. A drive detecting a valid Hard Reset sequence shall perform the 
equivalent of a power-on reset.
4.7K ohm pull-up resistors to 3.3V are provided on the drive for both DEV_CTRL_CODE_2, 
DEV_CTRL_CODE_1 and DEV_CTRL_CODE_0 to ensure that each signal is maintained in its high 
state unless a low is provided from the backplane.
Note: Please refer to the SFF-8045 Specification for more information.
Table 9.
DEV_CTRL_CODE_N Signal Definitions
DEV_CTRL_CODE_N
Link Rate
CODE_2
CODE_1
CODE_0
1.0625 GHz
1
1
1
2.1250 GHz
1
1
0
Reserved
1
0
1
Reserved
1
0
0
Reserved
0
1
1
Reserved
0
1
0
Reserved
0
0
1
Power Failure Warning
0
0
0