P0010 Startup Parameter Filter
Filters parameters, so that only parameters are selected that are assigned to a certain function
group. For example, the parameters needed for quick startups are displayed according to their
sequence.
The following settings are available
0: Ready
1: Quick startup
2: Converter
29: Download
30: Factory setting
•
P0010 = 0
To start the converter, P0010 has to be reset to 0.
•
•
P0010 = 1
The converter can be started up very quickly with the setting P0010 = 1. After that, only the most
important parameters are visible (for example, P0304, P0305, etc.). The individual parameter values
have to be entered successively.
The startup is completed and internal calculation is started by setting P3900 = 1 to 3. Then, the
parameters P0010 and P3900 are automatically set to zero.
•
important parameters are visible (for example, P0304, P0305, etc.). The individual parameter values
have to be entered successively.
The startup is completed and internal calculation is started by setting P3900 = 1 to 3. Then, the
parameters P0010 and P3900 are automatically set to zero.
•
P0010 = 2
Only for service purposes
•
•
P0010 = 29
To transfer a parameter file by means of a PC tool (such as STARTER), the PC tool sets the
parameter P0010 to 29. As soon as the data is downloaded, the PC tool resets the parameter
P0010 to zero.
•
parameter P0010 to 29. As soon as the data is downloaded, the PC tool resets the parameter
P0010 to zero.
•
P0010 = 30
If the parameters of the converter are reset, P0010 has to be set to 30.
The reset is started by setting P0970 = 1. The converter automatically resets all parameters to their
factory setting. This can be of advantage if problems arise while parameters are configured, and the
parameters have to be reconfigured. The reset to the factory settings takes approx. 60s.
Modifiable depending on the converter state
In addition, "P"-parameters can be modified only depending on the state of the converter.
For example, the parameter for quick startups P0010 (with the attribute "CT" in the parameter list)
can be modified only in the quick startup "C" or in the ready mode "T"; not, however, in the "U"
mode.
The reset is started by setting P0970 = 1. The converter automatically resets all parameters to their
factory setting. This can be of advantage if problems arise while parameters are configured, and the
parameters have to be reconfigured. The reset to the factory settings takes approx. 60s.
Modifiable depending on the converter state
In addition, "P"-parameters can be modified only depending on the state of the converter.
For example, the parameter for quick startups P0010 (with the attribute "CT" in the parameter list)
can be modified only in the quick startup "C" or in the ready mode "T"; not, however, in the "U"
mode.
State
Description
Quick startup
Operation (drive is running)
Operation (drive is running)
Drive ready