SeaLand 1 2500 Series User Manual

Page of 12
8
 OPERATION
DISPLAY PANEL
.
START-UP CHECKLIST
Before  first-time  use  of  the  2500  series  sanitation 
system, check the following:
•  The vacuum cassette tank is inserted correctly.
•  The fresh water supply tank is full.
•  The power supply is on.
GREEN – Ready to flush.
RED – Cassette full, or cassette  
removed, or undervoltage.  
Toilet cannot be flushed.
YELLOW – Vacuum pump is running.  
Do not flush toilet.
LED
Flush toilet only when 
green LED is illuminated.
Never flush toilet while 
sitting on open toilet seat, 
or if the seat lid is up.
Do not flush any solid or 
non-dissolving objects 
such as paper towels, 
plastic cans. They can 
plug or damage system.
The yellow LED illuminates for about one minute. 
Then the green LED illuminates. 
THE SYSTEM IS READY FOR OPERATION.
FLUSHING THE TOILET
1.  Make sure there is enough water in the bowl to 
cover the flush ball and seal in bottom of bowl. Lift 
pedal to add water to bowl (if needed for flushing 
solids).
2.  To flush, press pedal down to floor and hold down 
for 2 or 3 seconds. Keep seat lid closed to reduce 
noise.
3.  The  toilet  will  flush  liquids  effectively  with  only  
1 pint (0.4 liters) of water per flush.
4.  Use  only  rapid-dissolving  toilet  paper  designed 
for low water flow toilets. Some residential bath 
tissues may clog the system.
5.  If  the  cassette  tank  is  full,  the  
tank is removed from the  docking 
platform, or the voltage is too low, 
the  red  LED  illuminates  and  the 
system switches off. The system 
cannot be used until the cassette 
is emptied, inserted properly in the 
docking platform, and the correct 
voltage is restored.
REMOVING CASSETTE TANK  
(model 2510)
1.  Raise  the  latch  (A).  Holding  the  carrying 
handle (B), pull cassette straight back.
2.  When reattaching cassette tank, make sure 
it  is  placed  correctly  on  docking  platform. 
Make sure latch engages after pushing tank 
into platform.
A
B