Schlage CO-100 User Manual
9
CO-100 Offl ine Lock User Guide
BATTERIES
Installing or Replacing Batteries
1. Remove the battery cover.
2. Remove the Battery Bracket.
3. Install the new batteries. Observe polarity. (Install only new AA Alkaline batteries.)
4. Install the Battery Bracket.
5. Connect the batteries.
6. Reinstall the battery cover.
!
CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with
new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s
instructions.
new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s
instructions.
CY, MS, & MD
993
!
Plug MUST Be on Right
Low Battery Indications
Changing batteries does not affect any programmed data.
Condition
Indicator
Solution
Batteries Low
After credential PIN is pressed, 9 red
blinks of Schlage button, then normal
indicator.
blinks of Schlage button, then normal
indicator.
Replace batteries immediately to
avoid battery failure. Lock is intended
to operate for 500 cycles in low
battery condition.
avoid battery failure. Lock is intended
to operate for 500 cycles in low
battery condition.
Battery Failure
No LED or beeps
Valid credentials do not grant access
Replace batteries immediately.
Mechanical override key must be
used to unlock lock.
used to unlock lock.
Battery Failure Mode
In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or unlocked,
until batteries are replaced).
until batteries are replaced).