Sanyo PJ MASTER POA-PJNM01 User Manual

Page of 54
30
Chapter 3 Basic operation
Warning time/temperature setting
1. Select a target on the status list view window or a server on the tree view window.
-  When setting the multiple targets together, select targets and/or servers on the status list view win-
dow with pressing “Shift” or “Control” key.
-  If you select the server on the tree view or status list view window, the setting will be effected to the 
targets linked under the selected server.
2.  Select  Warning Setting from Projector menu. The setting window will appear. The current setting 
value of the selected target will be displayed on the window. When selecting the multiple target, 
it displays the last setting value.
3.  Enter the threshold value of warning time, or internal temperatures A, B or C of the target.
4. Click 
OK to set the warning setting. The setting window will close.
*  0 to 99999 hours can be set for warning time, and 0 to 99.9 degrees in Celsius or 32.0 to 211.9 degrees 
in Fahrenheit can be set for warning temperature.
* The default values are as follows;
 
Warning Time: 99999 hours
 
Warning Temperature: 99.9 degrees in Celsius or 211.9 degrees in Fahrenheit