Pelco PelcoNet Multimedia Transmission Via Network Net350 User Manual

Page of 92
C2907M-D (4/05)
79
4. Attach the cable’s DB9 connector end to PelcoNet’s COM1 port. Connect the cable’s RJ-45 connector end to COM out on the back of the 
multiplexer.
5. Connect the MAIN video output from the multiplexer to the NET350 transmitter.
6. Connect PelcoNet’s Ethernet port to the network using a Cat5 Ethernet patch cable.
CONNECTING PELCONET TO A CM6700 AND KBD200A FOR REMOTE ASCII CONTROL 
Figure 56.  Using PelcoNet with CM6700 and KBD200A to Provide Remote Control
Video In
75
Audio I/O
Power
TRANSMITTER
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
NOTE:  FIRMWARE VER 4.0 OR LATER REQUIRED. SET KEYBOARD DIP SWITCHES – SWITCH
6 ON, SWITCHES 5 AND 8 OFF, SWITCHES 1-4 FOR ADDRESS ACCORDING TO THE
TABLE IN THE KBD200A MANUAL.
1
3
5
7
9
2
4
6
8
10
11
12
14
13
15
16
1
2
VIDEO INPUTS
VIDEO OUTPUTS
ALARMS
(1-9)
ALARMS
(10-18)
COM 1 (1-6)
COM 2 (7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
1 2 3 4 5 6 7 8 9
10 11 1213 14 15 16 17 18
1 2 3 4 5 6 7 8 9 10 11 12
0 1 2
3
F
2
F
3
N
O
N
C
C
O
M
T T
R R
+
+
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
RS-422/485
ON
OFF
KEY
RS-232
SW5 DIP SWITCH SETTINGS
SET DIP SWITCH (SW5) ON
CM6700-MXB TO RS-232 MODE
CM6700 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
CONNECT PELCONET TO
6700 VIA RS-232 PORT
Video Out
75
Audio I/O
Power
RECEIVER
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
TX+
RX-
12 VAC
KBD200A
STRAIGHT
CABLE
1
2
3
4
8
7
6
5
RX+
TX-
SPECTRA COAXITRON
PROTOCOL
2-RX
3-TX
G-GND
PELCONET REMOTE KBD200A ASCII MODE SETUP
COM2:
RS232
COM1:
RS232/422/485
PELCONET
TRANSPARENT
DATA PORT
2 RX............................
3 TX...........................
5 GND.....................
CM6700-MXB
COM 2 (7-12)
7  TX
12 RX
9 GND
COM2:
RS232
COM1:
RS232/422/485
TRANSPARENT DATA PORT
USING INTERNET EXPLORER, SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1