TIC-LF502A
 
TIC-LF502A 
 
 
 
Table 1.  Specification Code for LF502 detector 
Model Specification 
Code 
Size 
1 2 3 4 5 6 7 8 9 10 11 12 
Description 
A B 
F 5 0 2        LF502 
Electromagnetic 
flowmeter 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Meter size 
 
 
     K        6" 
(150mm 
 
     L        8" 
(200mm 
 
     M       10" 
(250mm 
 
     N       12" 
(300mm 
 
     P       14" 
(350mm 
 
 
 
 
 
  Q 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
16" (400mm ) 
  20" (500mm ) 
24" (600mm ) 
 

 
 
 
 
 
 
 
  A   
 
 
 
  Standard 
 
 
 
 
 
 
 
 
 
 
    Connection 
flange 
standard 
 
 
 
 
 
 
 
 
  C       ANSI 
150 
 
 
 
 
 
 
 
 
 
J       JIS 
10K 
 
 
 
 
 
 
 
 
 
 
 
 
  Lining 
 
 
        C     Chloroprene 
rubber 
 
        D     EPDM 
rubber 
 
 
        T     Teflon 
PFA 
 
   
 
 
 
 
 
 
 
 
 
  Electrode and Grounding Ring Material 
 
 
   
 
 
 
 
 
 
  B   
 
316L stainless steel + 316 stainless steel  
 
 
         C    Titanium 
Titanium 
 
 
   
 
 
 
 
 
 
  F   
 
Hastelloy C + Hastelloy C 
 
 
   
 
 
 
 
 
 
  H   
 
316L stainless steel + 304 stainless steel 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Flow and calibration velocity range 
 
 
 
 
 
 
 
 
 
 
 
  A       Standard range calibration 
 
 
 
 
 
 
 
 
 
 
 
 
 
    Coating 
 
 
 
 
 
 
 
 
 
 
 
 
  B     Phthalic acid resin 
 
 
 
 
 
 
 
 
 
 
 
 
  C     Black tar epoxy resin , thickness 0.3mm 
 
 
 
 
 
 
 
 
 
 
 
 
  D     Black tar epoxy resin , thickness 0.5mm 
 
 
 
 
 
 
 
 
 
 
 
 
  E     Black tar epoxy resin , thickness 0.5mm (for submersible type) 
 
 
Code explanation:      : Standard      : Option      –: Not available 
 
Size groups 
A : 6” (150mm ) to 16” (400mm ) 
B : 20” (500mm ) and 24” (600mm ) 
 
 
Table 2. Specification Code for LF232*F converter 
 
Model Specification 
Code 
1 2 3 4 5 6 7 8 9 10 11 12 
Contents 
LF232 
type 
F 2 3 2        Separate type converter 
 
   
 
 
 
 
 
 
 
 
 
   
 
 
 
 
A             
Purpose 
Standard 
 
 
   
 
 
 
 
 
 
 
 
 
  Compatible detectors  
For Partially-filled pipes (Meter size : 150mm(6”) to 600mm(24”) ) 
 
 
   
 
 
 
 
   

 
 
 
  Mounting nuts and bolts 
Panel, wall mounting (material : 304 stainless steel) 
Pipe mounting            (material : 304 stainless steel) 
 
 
 
   
 
 
 
 
 
 
 
1
 
3
 
 
 
 
  Digital input/output 
Current output  
+ Digital output points (1 point) 
Current output 
  + Digital output points (4 points) + Digital input points  (2 points) 
 
 
 
 
   
 
 
 
 
 
 
 
 
  Communication function 
    HART communication 
 
 
   
 
 
 
 
 
 
 
 
 
  Power supply 
100Vac-120Vac, 50/60Hz 
 
 
   
 
 
 
 
 
 
 
 
  A  Standard 
 
Code explanation:      : Standard      : Option 
 
 
 
ISO9001 and ISO14001 certified. 
Misuse of this product can result in damages to property or human injury.  
Read related manuals carefully before using this product.
 
Specifications are subject to change without notice.
Printed in Japan 2008-5 (TDOC)
© TOSHIBA Corporation 2008
All Rights Reserved.
http://www.toshiba.com/ind/