Toshiba LF232*F Instruction Manual

Page of 8
 
TIC-LF502A 
  
 
Introduction 
The LF502 electromagnetic flowmeter uses Faraday’s 
Law of electromagnetic induction in the same way as 
conventional electromagnetic flowmeters to measure 
the flow rate. Position of electrodes in the LF502 is so 
designed that it can be used even in a partially-filled 
pipe to measure the flow rate. 
Improved functional magnetic field distribution 
technique enables a high-precision flow measurement 
continually from low-level to fully-filled flow 
conditions. This
 
eliminates
 
unnecessary
 
piping
 
work
 
such
 
as
 
lifting the downstream pipe section to fill the 
detector pipe. 
Compared with flowmeters measuring the flow rate by 
means of flow level, the obstruction less LF502 
flowmeter does not usually allow mud, sands and other 
solid sediment stay at the bottom of the detector pipe 
and
 
is
 
unaffected
 
by
 
wave
 
or
 
floating
 
solids
 
on
 
the
 
fluid 
surface. 
The AF900 hand-held terminal (HART*
communicator) can be used to communicate with the 
flowmeter from a remote place.  
*1:  HART protocol (Highway Addressable Remote 
Transducer) is a communication protocol for industrial 
sensors recommended by the HCF
 
(HART
 
Communication
 
Foundation). 
 
 
Detector
 
Signal cable
 
Converter
 
Excitation cable 
Digital I/O
 
Power supply
4-20 mAdc 
 
Figure 1. LF502/LF232*F Configuration 
 
 
 
Figure 2.  LF502 Electromagnetic Flowmeter 
for Partially-filled Pipes 
Specifications 
■ 
Overall Specifications 
Measurement range: 
Meter size 
Measurement range 
6” (150mm) 
0 – 264 GPM(std) to 0 – 1320 GPM 
(0 – 60 m
3
/h  to 0 – 300 m
3
/h ) 
8” (200mm ) 
0 – 484 GPM(std) to 0 – 2420 GPM 
(0 – 110 m
3
/h  to 0 – 550 m
3
/h ) 
10” (250mm ) 
0 – 770 GPM(std) to 0 – 3850 GPM 
(0 – 175 m
3
/h  to 0 – 875 m
3
/h ) 
12” (300mm ) 
0 – 1100 GPM(std) to 0 – 5500 GPM
(0 – 250 m
3
/h  to 0 – 1250 m
3
/h ) 
14” (350mm ) 
0 – 1540 GPM(std) to 0 – 7700 GPM 
(0 – 350 m
3
/h  to 0 – 1750 m
3
/h ) 
16” (400mm ) 
0 – 1980 GPM(std) to 0 – 9900 GPM 
(0 – 450 m
3
/h  to 0 – 2250 m
3
/h ) 
20” (500mm ) 
0 – 3124 GPM(std) to 0 – 15620 GPM 
(0 – 710 m
3
/h  to 0 – 3550 m
3
/h ) 
24” (600mm ) 
0 – 4400 GPM(std) to 0 – 22000 GPM 
(0 – 1000 m
3
/h  to 0 – 5000 m
3
/h ) 
Note: Above flow rate is almost 0 – 3.28 ft/s (std) to 0 – 
16.4 ft/s (0 – 1 m/s  to 0 – 5 m/s ) flow velocity. 
Fluid-level range: 
Meter size 
Specification 
6” to 12” m 
(150 to 300m ) 
1-1/4”(30mm ) to fully-filled condition.
14” to 24” 
(350 to 600mm )
10% of inside tube diameter to 
fully-filled condition. 
Note: The fully-filled condition means a 100% of inside 
tube diameter. 
Accuracy: ±2% FS (when measurement range is 
standard) 
Note:
 
The accuracy is measured under standard 
operating
 
conditions
 
at
 
Toshiba's
 
calibration
 
facility. 
Electromagnetic Flowmeter for  
Partially-filled Pipes 
LF502/LF232*F
6” to  24” 
(
150
 
to
 
600
 
mm
 )
 
LF502
LF232*F