5
SCANNING OPERATION
46
2. Select scan type and
start scanning
1
While pushing [FUNC], push
[
(4)
PROG-S] for program scan or
[
(5)
AMWS] for auto-memory write
scan, then rotate [DIAL] to select
scanning frequency band.
• Confirm that the receive mode of
the selected scan band is FM and
also that the tuning step is equal
to or smaller than 20 kHz.
• If you want to search the entire
frequency range (0.5–1300 MHz)
skip this step.
2
Push [SCAN] to start scanning.
3
Push [SCAN] or [CLR] to stop scan-
ning.
SIGNAVI function
The SIGNAVI function activates while
paused during full, program or auto-
memory write scans in FM mode. It
searches for busy frequencies up to
100 kHz* (+100 kHz when scanning up,
–100 kHz when scanning down) from
the paused frequency (f
0
), then jumps
to the next busy frequency (f
1
) detected
(by SIGNAVI) when scan resumes.
*The SIGNAVI search range varies ac-
cording to tuning step settings. The
maximum range is 5 channels or steps
from the receive frequency, therefore,
the tuning step must be equal to or
smaller than 20 kHz.
1. Set SIGNAVI function
q
Push [V/M] to select VFO mode
(p. 11).
w
While pushing [FUNC], push
[
(6)
SIGNAVI].
• Displays “
SIGNAVI
” below fre-
quency.
6
SIGNAVI
VFO
FM
144.0000
SIGNAVI
FUNC
+
SCAN
VFO
FM
144.0000
Flashes while scanning