Oracle Vacuum Cleaner CPU-56T User Manual

Page of 145
Switch Settings
Installation
SPARC/CPU−56T
47
Switch
Description
No.
2
Enable termination for SCSI 2
OFF (default): Termination enabled
ON: Termination disabled
3
Enable termination for SCSI 3 (on I/O−board, if applicable)
OFF (default): Termination enabled
ON: Termination disabled
4
Reserved
SW4
1..2
VME Slot 1 Detection
SW4−1 OFF (default): Automatic VMEbus slot 1 detection enabled
SW4−1 ON and SW4−2 OFF: VME slot 1 function enabled
SW4−1 ON and SW4−2 ON: VME slot 1 function disabled
3
External VMEbus SYSRESET function
OFF (default): VMEbus SYSRESET generates on−board RESET
ON: VMEbus SYSRESET does not generate on−board RESET
4
VMEbus SYSRESET generation
OFF (default): On−board reset is driven to VMEbus SYSRESET
ON: On−board reset is not driven to VMEbus SYSRESET