FC-5 - Using the FC-5
 
15 
 
6.2 
Transmitting Commands via the Contact Closure 
You can use the FC-5 to transmit commands via the contact closure (see also 
): 
 
Figure 14: Transmitting Commands via the Contact closure 
The INPUTS contact closure remote control pins let you temporarily route an input 
to the output by momentarily attaching an input to the GND (Ground) pin (do not 
connect more than one PIN to the Ground PIN at the same time). In this example 
INPUT 3 is routed to the output, by temporarily attaching PIN 3 to PIN GND, and a 
Kramer switcher is connected to the COM2 port