Actions: 
•  Select Outbound Phone Book 
o
  Select Add Entry 
o
  Accept Any Number may be selected to allow unmatched destinations an alternative 
o
  Enter the number necessary to get out from the PBX system followed by the calling code of the 
destination in the Destination Pattern field 
o
  Enter the PBX access digit (same number as needed to get out of the PBX system) in the 
Remove Prefix field 
o
  Any digits that need to be added should be put in the Add Prefix field 
o
  Enter the IP address of the call destination (add a Description if you like) 
o
  Select a Protocol type (–SS models use SIP only, -FX models do not support H.323
ƒ
 For 
H.323: 
•  Enter Gateway settings 
ƒ
 For 
SIP: 
•  Select Transport Protocol, Proxy and URL if needed 
ƒ
 For 
SPP: 
•  Enter Registrar settings if needed 
o
 The 
Advanced Button will allow an Alternate IP Address to be entered for outbound traffic 
•  Select Inbound Phone Book 
o
  Select Add Entry 
o
  Accept Any Number for inbound traffic does not work when external routing devices are used 
o
  Enter any access digits followed by the local calling code in the Remove Prefix field 
o
  Enter any digits needed to access an outside line in the Add Prefix field 
o
  Select Hunting in the Channel Number field to have the VOIP use the next available channel 
o
  Add a description if you like 
o
  Call Forward may be set up (details available in Chapter 5) 
o
  Select Registration Option 
•  Repeat the Phone Book steps for any additional entries needed 
Save & Reboot 
Any time that you change settings on the VOIP unit, you must choose the Save & Reboot option; otherwise all 
changes made will be lost when the MultiVOIP is reset or shutdown.