Mitsubishi Electronics J2-JRSERIES MR-J2-03A5 User Manual

Page of 185
5 -  21
5. PARAMETERS
5.2.3
Using forward/reverse rotation stroke end to change the stopping pattern
The stopping pattern is factory-set to make a sudden stop when the forward/reverse rotation stroke end is
made valid. A slow stop can be made by changing the parameter No. 22 value.
Parameter No.22 Setting
Stopping Method
†††
0
(initial value)
Sudden stop
Droop pulses are reset to make a stop.
†††
1
Slow stop
Position control mode : The motor is decelerated to a stop in accordance with the
parameter No. 7 value.
Speed control mode
: The motor is decelerated to a stop in accordance with the
parameter No. 12 value.
5.2.4
Alarm history clear
The servo amplifier stores one current alarm and five past alarms from when its power is switched on first.
To control alarms which will occur during operation, clear the alarm history using parameter No.16 before
starting operation.
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleard)
Parameter No.16