2 SYSTEM CONFIGURATION FOR SINGLE CPU SYSTEM 
 
(b) If the slim type main base unit (Q3
†SB) is used 
System configuration 
00
1F
20
3F
40
5F
60
7F
80
9F
0 1 2 3 4
Slot No.
Slim type main base unit (Q35SB)
The above system assumes that each slot is loading with 
a 32-point module.
P
o
wer s
upp
ly
m
odul
e
CP
U m
odu
le
 
Maximum number of 
Extension Stages 
No extension allowed 
Maximum number of 
I/O modules to be 
installed 
5 modules 
Maximum number of 
occupied I/O points 
4096 
Main base unit 
Q32SB, Q33SB, Q35SB 
Extension base unit 
Cannot be connected. 
Extension cable 
Cannot be connected. 
Notes 
(1) Q61P-A1, Q61P-A2, Q62P, or Q64P cannot be used for the power supply module. 
Use Q61SP for the power supply module. 
(2) The slim type main base unit does not have an extension cable connector. 