Product and Cut-out Dimensions
Page 4 of 4
CS 1112 E Ceramic Double Burner CombiSet
– Wall frame
– Wall covering
x = thickness of the wall covering
– Countertop
– Countertop cut-out
Safety distances  to back wall
CS 1112 E Ceramic Double Burner CombiSet
If a wall covering is installed, a minimum safety distance must be maintained between the countertop cut-out 
and the covering, since high temperatures can damage these materials.
If the covering is made of a combustible material (such as wood), the distance between the countertop cut-out 
and the wall covering must be a minimum of 2" (50 mm)
p
– Minimum safety distance
with flammable materials 2" (50 mm)
with non-flammable materials 2" (50 mm) minus x
Safety distances to surrounding cabinetry
Recommended
Not Recommended
Not Permitted
and the wall covering must be a minimum of 2  (50 mm).
For coverings made of non-combustible materials (such as metal, marble, granite or ceramic tiles) the 
minimum safety distance  between the countertop cut-out and the wall covering must be 2" (50 mm) minus the 
thickness of the covering.
For example: thickness of wall covering 9/16" (15 mm) 2" (50 mm) - 9/16" (15 mm) = minimum safety distance 
1 3/8" (35 mm).
Recommended 
Not Recommended               Not Permitted
The appliance should only be installed as shown in the above illustrations while maintaining the 
required safety distances shown. Do not install the appliance between two tall cabinets, this is a 
fire hazard.
A distance of at least 2” (50 mm) must be kept between the countertop and the rear wall 
because of high temperature radiated.
The minimum distance required from the countertop cut-out to a side wall or tall cabinet right or 
left 2” (50 mm) (Location code 1)
Safety distance above the appliance 
The minimum safety distance given by the hood manufacturer 
must be maintained between the combiset and the hood above 
it. See the installation instructions for the hood for these safety 
measurements.
Notes
All installations must be done in accordance with local codes.
Drawing is not to scale
Specification Sheets OJS 02212012
If the hood manufacturers instructions are not available or if 
flammable objects are installed over the combiset (e.g. 
cabinets, utensil rail, etc.), a minimum safety distance of 30” 
(760 mm)  must be maintained.