Lynx D AD 3220 B User Manual

Page of 25
Reference Manual D AD 3220 B Version 1.0
 
 
Page 15  
 
 
Multiple Units 
When installing multiple MiniModule units it is 
recommended you use the R FR 3005 Rack Frame 1 
and / or R FR 3010 Rack Frame 2 options. Please 
refer to the documentation supplied with these 
options for details on electrical installation. 
 
Settings and Control 
 
The D AD 3220 B is configured via the integral 4-
position dip-switch. This is located on the bottom of 
the module and can be accessed through the 
cutout provided (fig 2) 
 
1 2 3 4
DIP Switch
ON
OFF
LED 2
LED 1
Channel 1 Status
Channel 2 Status
 
Switch Settings 
Below the switch settings for the 4-position dip-
switch are defined. Please see the section following 
the table for more detail on the switch function. 
 
 
 
 
 
 
  
Switch 
Setting 
Function 
ON Enable 
Local 
Adjustment 
OFF Disable 
Local 
Adjustment 
ON 
Dual 1 > 4 mode 
OFF 
Single 1 > 8 mode 
ON Not 
Used 
OFF Not 
Used 
ON Not 
Used 
OFF Not 
Used