Lynx D AD 3220 B User Manual

Page of 25
Reference Manual D AD 3220 B Version 1.0
 
Page 16   
 
Switch Function Detail 
All settings are stored in Flash Ram inside the 
module (see Auto Store section in this manual). 
Settings will be recalled on power up.  
 
Dip Switch 1   
This switch enables local control using the dip-
switches. ON enables local control and makes 
selections on the dipswitch active, and OFF 
disables local control (locking out any local 
changes) 
 
Note. 
When Switch 1 is initially switched to ON, the static 
settings currently set on the dip-switches may not 
reflect the actual configuration stored in the 
module. This is because all settings can be 
changed from the remote control system or via the 
Service Adapter. This overrides the local dip 
switches regardless of Switch 1 ON/OFF setting. To 
ensure the module reads the local dip switch 
settings it is recommended to toggle Switch 1 ON-
OFF-ON before making any local changes to the 
dip switches
 
Dip Switch 2  
This switch selects the mode of operation for the 
module. ON selects dual 1 into 4 mode where each 
individual AES input is distributed to four outputs. 
OFF selects 1 into 8 mode where input AES in 1 is 
distributed to all 8 outputs. 
 
Dip Switch 3 
This is not used 
 
Dip Switch 4 
This is not used