Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
730
IP Trunk Configuration Manager 
17
Internet dialog box
Use the Internet dialog box to configure your connection to an IP network. Adjust 
these parameters as needed for optimal performance. 
DTMF Duration: Sets the DTMF (Dual Tone Multi-frequency) 
duration for communication with an H.323 client.
Valid values: 
150
 to 
15000
 (milliseconds)
DTMF Silence Duration: Sets the silence duration interval 
between two consecutive DTMF tones for communication with an 
H.323 client. 
Valid values: 
30
 to 
15000
 (milliseconds)
Fax
Maximum Fax Rate: Indicates the fax transmission rate. 
Valid values: 
9.6
 Kpbs or 
14.4
 Kpbs.
Fax Error Control: Sets the level of redundant information used 
to improve the fax completion rate.
Valid values: 
None
 (no redundant information use)
Moderate
: Each packet transmitted also contains the previous 
packet sent.
Extensive
: Each packet transmitted also contains the previous two 
packets sent.
For good quality, managed networks with very little packet loss, 
use None. For a managed network with high packet loss, use 
Extensive to improve the fax completion rate. Extensive results in 
higher bandwidth usage and longer fax sending time.
Fax Frames Per Packet: Sets the number of fax frames per 
packet. 
Valid values: 
or 
2
.
Parameter
Description
Continued on next page