Lucent Technologies Medical Alarms Release 3 Version 8 User Manual

Page of 114
 
 
Administering the Switch for CMS High Availability Systems
 
CentreVu CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Administering the Definity Switch
4-14
Adding an Ethernet 
Data Module 
4
Use the Data Module form to assign an ethernet data module (this is a 
different version of the form than that used for 
DEFINITY R7). With the 
High Availability option, you assign two ethernet data modules.
add data-module 2000
 Page 
1 of
 1
DATA MODULE
Data Extension: 2000 
Name: ethernet data module
BCC: 2
Type: ethernet
Port: 01A0317
Link: 8
Network uses 1’s for Broadcast Address? y
Field
Definition
Data Extension
Enter an unassigned extension number.
Type
Enter
 ethernet
.
Port
Enter the equipment location of the C-LAN 
circuit pack (TN799). For the ethernet link, 
always use circuit 17 (for example, 
01A0317
).
Link
Enter a TCP/IP link number (1-25 for csi/si, 
1-33 for r). This entry is also used on the 
Processor Channel form.
Name
Enter a name for the data module. This name 
will display when you list the assigned data 
modules.
BCC
A display-only field.
Network uses 1’s for 
Broadcast Address
This sets the host portion of the IP address to 
0’s or 1’s. The default is yes (all 1’s). Use the 
default if the private network contains only 
DEFINITY switches and adjuncts. Enter n 
only if the network includes non-DEFINITY 
switches that use the 0’s method of forming 
broadcast addresses.