Lucent Technologies Medical Alarms Release 3 Version 8 User Manual

Page of 114
 
 
Administering the Switch for CMS High Availability Systems
 
CentreVu CMS R3V8 High Availability
Connectivity, Upgrade and Administration
Administering the Definity Switch
4-15
Adding the 
Processor Interface 
Channels
4
Use the Processor Channel form to assign the processor channel 
attributes. With the High Availability option, you will assign two separate 
processor channels.
change communication-interface processor-channels 
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc 
Gtwy
 Interface
 Destination
 Session
 Mach
Chan Enable
Appl.
To Mode Link/Chan
Node
Port
Local/Remote
ID
1:
y
mis
s
8
5001
cmshost
0
1
1
2:
y
mis
s
9
5001
cmshost2
0
1
1
3:
4:
Field
Definition
Proc Chan
Select a processor channel for this link. Use 
the first channel available.
Enable
Enter
 y
.
Appl
Enter
 mis
.
Gtwy To
Not used for CMS.
Mode
Enter
 s 
for server.
Interface Link
Enter the TCP/IP link number used on the 
ethernet data module form. For this series of 
examples, link
 8 
was used.
Interface Chan
Enter the TCP channel number 
(5000-64500). The default for CMS is 5001 
and is defined during CMS setup (see 
Destination Node
Enter the node name of the CMS computer 
as assigned on the Node Names form. In 
these examples,
 cmshost 
is used.
Destination Port
Use the default of
 0
.
Session Local/
Session Remote
Although not strictly required, the standard 
CMS provisioning practice is to set the local 
and remote port assignments equal to the  
processor channel assignment for each 
connection.
Mach ID
Not used for CMS.