  7: Line and Tunnel Settings 
PremierWave XC User Guide 
 
54
 
Tunnel Connect 
Mode Settings
 
Description 
Flush Serial Data  Sets whether the serial Line data buffer is flushed upon a new network connection.  
Choices are: 
 
Enabled = serial data buffer is flushed on network connection 
 
Disabled = serial data buffer is not flushed on network connection (default
Block Serial 
Set whether Block Serial is enabled for debugging purposes.  Choices are: 
 
Enabled = If Enabled, incoming characters from the Serial Line will not be forwarded 
to the network.  Instead, they will be buffered and will eventually flow off the Serial 
Line if hardware or software flow control is configured. 
 
Disabled = this is the default setting; incoming characters from the Serial Line are 
sent on into the network.  Any buffered characters are sent first. 
 
Any Character = a connection is attempted when any character is read on the serial 
line. 
 
Start Character = a connection is attempted when the start character for the selected 
tunnel is read on the serial line. 
 
Modem Control Asserted = a connection is attempted as long as the Modem 
Control pin (DSR) is asserted, until a connection is made. 
 
Modem Emulation = a connection is attempted when triggered by modem emulation 
AT commands. 
Block Network 
Set whether Block Network is enabled for debugging purposes.  Choices are: 
 
Enabled = If Enabled, incoming characters from the network will not be forwarded to 
the Serial Line.  Instead, they will be buffered and will eventually flow off the network 
side. 
 
Disabled = this is the default setting; incoming characters from the network are sent 
on into the Serial Line.  Any buffered characters are sent first. 
Email on 
Connect 
Select an email profile number to which an email notification will be sent upon the 
establishment of an accept mode tunnel. 
Email on 
Disconnect 
Select an email profile number to which an email notification will be sent upon the 
disconnection of an accept mode tunnel. 
To Configure Tunnel Connect Mode Settings 
Using Web Manager 
 
To configure the Connect Mode for a specific tunnel, click Tunnel in the menu and select 
Tunnel 1 -> Connect Mode
Using the CLI 
 
To enter the Tunnel 1 Connect Mode command level:  enable -> tunnel 1 -> 
connect
 
Using XML 
 
Include in your file:   <configgroup name="tunnel connect" instance="1">