Lantronix Network Hardware 900-598 User Manual

Page of 109
 
 
  7: Line and Tunnel Settings 
PremierWave XC User Guide 
 
56
 
Modem Emulation 
Some older equipment is designed to attach to a serial port and dial into a network with a modem.  
This equipment uses AT commands to control the connection.  For compatibility with these older 
devices on modern networks, our product mimics the behavior of the modem. 
Table 7-8 Tunnel Modem Emulation Settings 
 
Tunnel Modem Emulation 
Settings
 
Description 
 
Echo Pluses 
Set whether the pluses will be echoed back during a “pause +++ pause” 
escape sequence on the Serial Line.  Choices are: 
 
Enabled 
 
Disabled (default) 
 
Echo Commands 
Set whether  characters read on the Serial Line will be echoed, while the Line 
is in Modem Command Mode.  Choices are: 
 
Enabled 
 
Disabled (default) 
 
Verbose Response 
Set whether Modem Response Codes are sent out on the Serial Line.  
Choices are: 
 
Enabled 
 
Disabled (default) 
 
Response Type 
Select a representation for the Modem Response Codes sent out on the 
Serial Line.  Choices are: 
 
Text (ATV1) (default) 
 
Numeric (ATV0) 
 
Error Unknown 
Commands 
Set whether the Error Unknown Commands is enabled (ATU0) and ERROR is 
returned on the Serial Line for unrecognized AT commands.  Otherwise 
(ATU1) OK is returned for unrecognized AT commands.  Choices are: 
 
Enabled 
 
Disabled (default) 
 
Incoming Connection 
Set how and if requests are answered after an incoming RING (ATS0=2).  
Choices are: 
 
Disabled (default) 
 
Automatic 
 
Manual 
 
Connect String 
Enter the customized Connect String sent to the Serial Line with the Connect 
Modem Response Code. 
 
Display Remote IP 
Set whether the Display Remote IP is enabled so that the incoming RING 
sent on the Serial Line is followed by the IP address of the caller.  Choices 
are: 
 
Enabled 
 
Disabled (default)