Hughes DW6000 User Manual

Page of 174
Appendix C • Installing the DW6000 using Installer Console
1033295-0001 Revision 2
113
Antenna Pointing - Transmitter,
Manual
The manual cross-polarization function can be used to adjust the 
antenna and peak the antenna’s transmit polarization for 
maximum isolation. You can also use manual pointing to adjust 
polarization after failing the automatic cross-polarization test.
1. Enter 
at the 
Installation Menu
 prompt. The 
Antenna 
Pointing - Transmitter, Manual
 screen appears. 
Otherwise, the screen shows the current queue position until 
the test can be run. When the 
Test Status
 field shows 
Active 
the test can be run. The result of the test is shown in the 
Result:
 field, where a transmitter isolation value is reported. 
2. Make small, one-degree or less changes in polarization while 
observing the transmitter isolation. Peak the transmitter to the 
highest possible transmitter isolation value.
3. Press 
Enter
 to return to the 
Installation Menu
.
Antenna Pointing - Transmitter,
Automatic
Automatic cross-polarization (ACP) is used for a rapid Pass/Fail 
test of the antenna’s transmit polarization adjustment. If you pass 
ACP the unit is enabled and no further antenna pointing is 
needed. 
1. Enter 
at the 
Installation Menu
 prompt. The 
Antenna 
Pointing - Transmitter, Automatic
 screen appears. 
Otherwise, the screen shows your current queue position until 
the test can be run. (Sometimes a number of installers will be 
pointing their antennas at the same time. You may have to 
wait for the test to be run, and are placed in a queue until it 
can be run.)
The result of the test is shown in the 
Result:
 field. 
PASS
 
means the transmit modem will be enabled and the system 
should be operational. 
FAIL
 means the transmit modem will 
be disabled and the dish pointing needs to be checked.
2. Whether you pass or fail, press 
Enter
 to return to the 
Installation Menu
.
3. Enter 
z
 to return to the 
Main Menu
.
4. At the 
Main Menu
 enter 
c
. The 
Satellite Interface Statistics 
Menu
 appears (see Figure 105).
5. Enter 
a
. The 
Display Main Statistics
 screen appears. Confirm 
the SQF is greater than 31 and that the transmitter is 
available.
6. Enter 
z
 to return to the 
Main Menu
.