Honeywell Galaxy 3-48C Installation Instruction
Galaxy 3 Series Installation Manual
5-5
Removing MAX
3
Readers
Removing a MAX
3
Reader from the System
On-Line Mode
1.
Access engineer mode.
2.
Disconnect the MAX
3
reader (AB line and power).
3.
Exit engineer mode.
4.
The message 1 MOD. MISSING — [<],[>] to View is displayed.
5.
Press the A or B key.
6.
The message MAX XX —º =REMOVE MODULE is displayed.
7.
Press the º key to acknowledge and accept that the MAX
3
reader has been removed. The keypad
returns to the unset banner.
Operating Instructions
The MAX
3
must be presented with a valid user card to allow access. Opening the door without presenting a
valid card activates a door forced alarm at the panel; the buzzer sounds and LED 2 flashes until the door is
closed.
Activating the egress switch allows the door to be opened without activating an alarm when no card
has been presented to the MAX
closed.
Activating the egress switch allows the door to be opened without activating an alarm when no card
has been presented to the MAX
3
.
1. Ensure that LED 3 is on and all other LEDs are off.
2. Swipe the MAX with a standard user or nightlock access user card. LED 3 switches off and LED 2
2. Swipe the MAX with a standard user or nightlock access user card. LED 3 switches off and LED 2
switches on for the programmed Open Timeout.
3. Open the door while the LED 2 is on and access the area.
4. Close the door; LED 2 switches off and LED 3 switches on. The door must be closed within the
4. Close the door; LED 2 switches off and LED 3 switches on. The door must be closed within the
programmed Close Timeout; if the door remains open longer than this, an alarm is activated.
Card-Held Function
The MAX
3
card can be assigned a single menu option (refer to option 42.1.8 = CODES.User Codes.MAX
Function). To activate the function assigned to the MAX
3
card, hold the card in front of the reader for three
seconds; all of the LEDs switch on. If a keypad has been assigned to the MAX function then it displays the
details of this option. If no keypad is assigned, pressing a key on any of the keypads assigned to a common
group to the user displays the card-held function.
details of this option. If no keypad is assigned, pressing a key on any of the keypads assigned to a common
group to the user displays the card-held function.
Card-Held System Setting
If the MAX
3
card is assigned one of the setting options (option 12, 13, 14 & 16 – 19), the card-held func-
tions starts the setting procedure for the groups assigned to the card.
NOTE: If Group Restriction is assigned, then only the groups that are common to both the MAX
3
reader
and the MAX
3
user are set/unset
To unset the system using the MAX
3
, swipe the reader with a valid MAX
3
card. The MAX
3
reader beeps.
All of the groups assigned to the card are instantly unset.
All new MAX