Honeywell Galaxy 3-48C Installation Instruction

Page of 90
Galaxy 3 Series Installation Manual
5-5
Removing MAX
3
 Readers
Removing a MAX
3
 Reader from the System
On-Line Mode
1.
Access engineer mode.
2.
Disconnect the MAX
3
 reader (AB line and power).
3.
Exit engineer mode.
4.
The message 1 MOD. MISSING  [<],[>] to View is displayed.
5.
Press the A or B key.
6.
The message MAX XX —º =REMOVE MODULE is displayed.
7.
Press the º key to acknowledge and accept that the MAX
3
 reader has been removed. The keypad
returns to the unset banner.
Operating Instructions
The MAX
3
 must be presented with a valid user card to allow access. Opening the door without presenting a
valid card activates a door forced alarm at the panel; the buzzer sounds and LED 2 flashes until the door is
closed.
Activating the egress switch allows the door to be opened without activating an alarm when no card
has been presented to the MAX
3
.
1. Ensure that LED 3 is on and all other LEDs are off.
2. Swipe the MAX with a standard user or nightlock access user card. LED 3 switches off and LED 2
switches on for the programmed Open Timeout.
3. Open the door while the LED 2 is on and access the area.
4. Close the door; LED 2 switches off and LED 3 switches on. The door must be closed within the
programmed Close Timeout; if the door remains open longer than this, an alarm is activated.
Card-Held Function
The MAX
3
 card can be assigned a single menu option (refer to option 42.1.8 = CODES.User Codes.MAX
Function).  To activate the function assigned to the MAX
3
 card, hold the card in front of the reader for three
seconds; all of the LEDs switch on.  If a keypad has been assigned to the MAX function then it displays the
details of this option.  If no keypad is assigned, pressing a key on any of the keypads assigned to a common
group to the user displays the card-held function.
Card-Held System Setting
If the MAX
3
 card is assigned one of the setting options (option 12, 13, 14 & 16 – 19), the card-held func-
tions starts the setting procedure for the groups assigned to the card.
NOTE: If Group Restriction is assigned, then only the groups that are common to both the MAX
3
 reader
and the MAX
3
 user are set/unset
To unset the system using the MAX
3
, swipe the reader with a valid MAX
3
 card.  The MAX
3
 reader beeps.
All of the groups assigned to the card are instantly unset.
All new MAX
3
 readers default to address 7.