Parameter
Description
Motor rated current
Motor nameplate current. Amps
Motor rated voltage
Motor nameplate voltage. Volts
Crossover Voltage
Voltage at which field weakening begins. RMS volts
Motor rated power
Motor nameplate power. Kilowatts or Horsepower
Motor rated freq
Motor nameplate frequency. Hertz
Motor rated rpm
Motor nameplate speed. RPM
Motor poles
The number of magnetic poles in the motor. If this
parameter is left blank, the control determines the
number of poles from parameters Motor rated freq
and Motor rated rpm. In the case of some lower speed
motors (less than 900 rpm at 60 hz) with high slip, this
determination may not be accurate and parameter
Motor poles must have the correct value entered.
Unitless.  Must be an even whole number.
Applied top RPM
Top application speed. RPM
Reflected indication variables
The Innovation Series drive contains a variable copy of some of the primary motor
and application parameters. The following table lists the variable reflections of the
primary value parameters:
Variable
Description
100% Motor current
Motor nameplate current. RMS amps
100% Motor voltage
Voltage at which field weakening begins. RMS volts
100% Motor power
Motor nameplate power. Kilowatts or Horsepower
100% Applied RPM
Top application speed used in overspeed fault
protection and other areas of motor control. RPM