Epson G3 Series User Manual

Page of 92
Setup & Operation    5. Motion Range 
 
G3 Rev.1 
47 
 
5.1    Motion Range Setting by Pulse Range (for All Joints) 
Pulses are the basic unit of Manipulator motion.    The motion range of the Manipulator is 
controlled by the pulse range between the pulse lower limit and upper limit of each joint. 
Pulse values are read from the encoder output of the servo motor. 
For the maximum pulse range, refer to the following sections. 
The pulse range must be set inside of the mechanical stop range. 
5.1.1 Max. Pulse Range of Joint #1 
5.1.2 Max. Pulse Range of Joint #2 
5.1.3 Max. Pulse Range of Joint #3 
5.1.4 Max. Pulse Range of Joint #4. 
)
NOTE
 
Once the Manipulator receives an operating command, it checks whether the target 
position specified by the command is within the pulse range before operating.  If the 
target position is out of the set pulse range, an error occurs and the Manipulator does not 
move. 
 
 
EPSON 
RC+ 
 
The pulse range can be set on the [Range] panel shown by selecting [Tools]-[Robot 
Manager].    (You may also execute the Range command from the [Command Window].)