Emerson Dual Conversion Online UPS GXT3-6000RT208 User Manual

Page of 52
Installation and Configuration
14
The adjustable rack-mounting brackets (Part#: RMKIT18-32) feature retaining latches to prevent 
users from inadvertently sliding the UPS or battery cabinet out of the rack.
To install the rack mount brackets:
1. Unpack two rack-mounting bracket assemblies and 
mounting hardware from this kit. Bracket assemblies are 
interchangeable between left-hand or right-hand. 
Remove inner member of each bracket assembly as shown 
at right by extending it to its outermost position, depress-
ing the retaining latch and then pulling the inner member 
out of the bracket assembly.
2. Determine the height position inside the rack enclosure 
where you want to mount the UPS or battery cabinet.
3. Install the rear member of each bracket assembly into the 
rack enclosure with two M5 screws provided in this kit (see 
figure at right). The return flanges on the bracket assembly 
fit to the inside of rack mounting rails. Insert screws 
loosely (finger-tight) into the top and bottom holes of the 
return flange on the rear member. Extend the bracket 
assembly by sliding the front member forward until it 
touches the front rack mounting rail. Insert two M5 screws 
loosely (finger-tight) into the top and bottom holes of the 
return flange on each front member. Make sure that the 
bracket assemblies are at the same mounting height on all 
four (4) rack mounting rails.
4. Get eight M4 screws and eight M4 nuts from the hardware 
pack in this kit. Each nut has a locking, nylon insert that 
begins gripping the screw when it is halfway tight. Make 
sure to tighten the nut and screw completely to ensure 
locking action. Fasten the rear member and the front 
member together using four screws and four nuts per 
bracket assembly as shown in at right. For maximum 
support, insert fasteners for each bracket assembly as far 
apart as possible, depending on rack depth, while still 
joining both members (see figures at right). Check 
alignment of bracket assemblies and TIGHTEN ALL 
SCREWS FROM Steps 2 and 3.
5. Prepare the UPS or battery cabinet (the “equipment”) for 
rack mounting by following instructions in the equipment’s 
user manual. The equipment may require additional parts 
to be added or parts to be removed for rack mounting. After 
it is prepared, lay the equipment in rack-mounting 
position. Fasten the inner members from Step 1 to the 
equipment on both sides as shown at right with eight M4 
screws provided in the kit. Make sure retaining latch is 
near the rear of the equipment as shown (see figure at 
right).
!
CAUTION
Reduce the risk of tipping the rack enclosure by 
placing the UPS or battery cabinet in the lowest 
possible rack position.
Return 
flanges
Inner 
members
Front 
members
Retaining 
Latches
M5 screws
M5 screws
Front rack 
mounting rails
457mm 
(18") 
rack 
depth
M4 nuts
M4 nuts
M4 
screws
813mm 
(32") rack 
depth
M4 nuts
M4 nuts
M4 
screws
UPS or battery 
cabinet
Front
M4 screws
M4 screws
Retaining latch