EMC DS-16B2 User Manual

Page of 64
3
3-8
Departmental Switch Model DS-16B2 Fabric OS Procedures Manual
Displaying Error Logs and Status
Displaying the Temperature Status
To display the temperature status of a switch:
1. Login to the switch as the admin user.
2. At the command line enter the following command:
tempShow
This command displays current temperature readings from each 
of the five temperature sensors located on the main printed circuit 
board of the switch. The sensors are located, approximately, one 
in each corner and one at the center of the PCB.
Running Diagnostic Tests on the Switch Hardware
There are several diagnostic tests you can run on a switch. These tests 
are generally run during the 
POST
, each time a switch is booted up.
camtest
centralMemoryTest
cmemRetentionTest
cmiTest
crossPortTest
portLoopbackTest
sramRetentionTest
turboRamTest
statsTest
spinSilk
supportShow
The 
supportShow
 command is used to gather switch information for 
debugging purposes. Your EMC Customer Service representative 
may ask you to run this command and capture the output. This 
information will aid Customer Service in diagnosing problems that 
could occur on the switch.