EMC DS-16B2 User Manual
3
3-10
Departmental Switch Model DS-16B2 Fabric OS Procedures Manual
Displaying Error Logs and Status
Operands
This command has the following operands:
firstPort
Specify the first port, of a range of ports, to dump
information. The default (if no operand specified) is to print state of
port 0. If only
port 0. If only
firstPort
is specified, only information for
firstPort
is printed.
lastPort
Specify the last port, of range of ports, to dump
information.
nLog
Specify the number of lines of portLogDump to print:
0 = dump all lines (default)
N = dump the last N lines
<0 = skip portLogDump
Example
If
firstPort
is specified but
lastPort
is not specified, only
firstPor
t information is printed for the port-based commands
(portShow, portRegShow, portRouteShow
). If no operand is
supplied,
firstPort
is set to
0
and
lastPort
is set to maximum port
of switch.
sw7:admin> supportShow
Kernel: 5.3.1
Fabric OS: v2.1
Made on: Tue Apr 6 16:57:22 PDT 1999
Flash: Thu Apr 1 10:23:43 PST 1999
BootProm: Thu Oct 1 13:34:29 PDT 1998
37 34 37 45 49 Centigrade