2. INSTALLATION
 
 
2-21
4.  Choose INT or EXT as appropriate. Normally choose INT. If own GPS sensor 
is not working and a heading sensor such as a gyrocompass is available, 
choose EXT. 
5.  Press the [ENT] key. 
6.  Press the [DISP] key to close the menu. 
 
 
2.7 
Connection of External Equipment 
2.7.1 General 
wiring 
All external equipment are terminated on the MAIN Board inside the processor 
unit. Turn off the power and unfasten four screws to remove the cover. Connect 
wiring from external equipment referring to the interconnection diagram. Use the 
lever supplied to open terminal blocks, referring to the instructions below. 
From top: Analog Roll, Analog Pitch, 2-pole)
 
LOG/ALARM (Contact signal, 6-pole)
Recommended Cables*:
Power cable:
DPYC-1.5
IEC 61162 equipment: TTYCS-1
AD-10 equipment:
TTYCS-1Q
1. Insert lever.
2. Press lever.
3. Insert core.
4. Release lever.
Lever
How to insert cores in terminal blocks
DATA IN (AD-10/IEC 61162-1/2, 5-pole)
BEACON EXT (RTCM SC-104, 3-pole)
DATA OUT6 (AD-10, 4-pole)
DATA OUT1-DATA OUT5 (AD-10/IEC 61162-1/2, 4-pole) 
Power Cable
* Or equivalent
 
Processor unit, cover opened