Table 2.11
Power distribution unit (1U) breaking characteristics (Trip time (sec.))
Figure 2.7
Example of a power supply connection using a power distribution unit (1U)
Delay
100%
125%
150%
200%
400%
600%
800%
1000%
200E
No Trip
45 to 
500
15 to 
250
6 to
 90
0.7 to
 15
0.008 to
 5
0.006 to
 0.4
0.004 to
 0.08
CP
To power supply facility
To power supply facility
CP
Power distribution unit
Line 0
Line 1
CE
DE #01
ETERNUS DX Disk storage system
CP
CP
CP: Circuit Protector
Distribution 
board
Distribution 
board
PSU
PSU
PSU