Fostex PD606 User Manual

Page of 226
76
Location Recorder  Model PD606
Chapter 5: Recording/Playback
You can select a sampling frequency and bit length combination.
Sampling frequency and bit length selection [ 
 ]
<Note>: 
When "DIGI" (or "WORD" or “VIDEO”) is selected but the unit does not re-
ceive a correct digital (or word or video) signal or does not lock to the reference
signal, "DIGI" (or "WORD" or “VIDEO”) quickly flashes. In such a case, check cable
connection, etc.
<Note>: 
When the system clock is set to "DIGI" or "WORD", the FS of a file to be
played back must match the FS setting of the unit. Otherwise, you cannot play back
the file. In such a case, make the FS setting of the unit to match the FS of the file.
<Note>: 
The relation between the number of recording tracks and the Fs/Bit setting
is shown on page 84.
<Note>: 
If you change the FS/BIT setting during recording, the new setting is not
valid until recording stops.
You can select a sampling frequency and bit length combination also via the "Record FS&Bit"
menu item in the "SYS SETUP" menu of the MENU mode (see page 144 for details).
Available FS/BIT options (default: 48/24)
44.1/16, 44.1/24, 48/16, 48/24, 88.2/24, 96/24, 176.4/24, 192/24
You can select the recording mode of the LTC generated by the internal TC generator or
external time code.
TC generator mode setting (TC recording mode) [ 
 ]
You can make the pull up/pull down setting of the sampling clock/internal TC frame rate
when the clock reference is set to "INT".
Clock pull up/pull down setting [ 
 ]
<Note>: 
You can set the default LTC start time via the "Default LTC Start" menu item
in the "TC SETUP" menu of the MENU mode (see page 190).
You can also select the TC recording mode via the "Gen mode" menu item in the "TC SETUP"
menu of the MENU mode (see page 183).
Available TC recording mode options (default: Rec-Run)
FREE (Free Run), Rec-R (Rec-Run), 24H-R (24H-Run), EXT (Ext Run)
Available pull up/pull down options (default: 0.0%)
+0.1%, 0.0%, -0.1%
<Note>: 
The sampling frequency of the digital input signal must match the Fs/Bit
setting of the PD606.