FIC M295 User Manual

Page of 175
 
Software Functional Overview 
 
Register 
Bit Number 
Function  Address 
Name 
R/W 
7  6
5
4
3
2
1
0
Logic Default Description 
1Ah 
*3 
Battery State  R(/W) 
DATA[15:3] *1 
All bits are 0 
C
R
T
C
H
G
D
C
H
G
- - 
DCHG=1: 
CHG  =1 : 
CRIT =1 : 
The battery is 
discharged 
The battery is 
charged 
The battery is 
critical (Empty) 
1Ch 
*3 
Battery 
Present rate 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mW) 
0xffff: Unknown 
1Eh 
*3 
Battery 
Remaining 
Capacity 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mWh) 
0xffff: Unknown 
1
st
 Battery 
[ _BST ] 
20h 
*3 
Battery 
present 
Voltage 
R(/W) DATA[15:0] 
*1  - 
0xffff 
0x0000-0xfffe(mV) 
0xffff: Unknown 
1
st
 Battery 
[ _BTP ] 
22h 
Battery Trip 
Point 
R/W DATA[15:0] 
*1 - 
0x0000
0x0000 :Clear the trip point 
0x0001-0xffff(mWh) 
2
nd
 
Battery 
[ _BIF ] 
 
24h 
to 
3Ch 
*3 
*2 *2 
*2 
*2 *2 
*2 
 
2
nd
 
Battery 
[ _BST ] 
3Eh 
to 
44h 
*3 
*2 *2 
*2 
*2 *2 
*2 
 
2
nd
 
Battery 
[ _BTP ] 
46h *2 
*2 
*2 
*2 
*2 
*2 
 
48h 
Battery data 
Size 
 
R(/W) 
DATA[7:0] 
     - 
0x01 : DATA size is 3byte.(PMU06A)
0x00 :DATA size is 2 byte. (PMU06)   
*8 
49h 
Design 
capacity
 
R(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 02/03h. 
*7 *8  
1
st
 Battery 
[_BIF] 
4Ah 
Last Full 
Charge 
Capacity
 
R(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 04/05h. 
*7 *8 
1
st
 Battery 
[_BST] 
4Bh 
Battery 
Remaining 
Capacity
 
R(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 1E/1Fh. 
*7 *8 
1
st
 Battery 
[_BTP] 
4Ch 
Battery Trip 
Point
 
R(/W) 
DATA[23:16] *1 *7 
0x00 
PMU06A use this data with 22/23h. 
*7 *8 
4Dh 
Design 
capacity
 
R(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 26/27h. 
*7 *8 
2
nd
 
Battery 
[_BIF] 
4Eh 
Last Full 
Charge 
Capacity
 
R/(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 28/29h. 
*7 *8 
2
nd
 
Battery 
[_BST] 
4Fh 
Battery 
Remaing 
Capacity
 
R(/W) 
DATA[23:16] *1 *7 
0xff 
PMU06A use this data with 42/43h. 
*7 *8 
2
nd
 
Battery 
[_BTP] 
50h 
Battery Trip 
Point
 
R(/W) 
DATA[23:16] *1 *7 
 
0x00 
PMU06A use this data with 46/47h. 
*7 *8 
 
51h 
to 
6Bh 
*3 
Reserved 
R/W 
Don’t care 
  
 
*1: 
The register type is word. 
*2: 
Same as 1st Battery CMBatt Data 
*3: 
This register is not cleared if the system is in S4-S5 state. 
R(/W): 
This is the read only register, but the written data will be able to read back till PMU updates the data 
periodically, or PMU detects the status change. 
 
FIC M295 / M296 Service Manual 