Console Commands
AlarmConfig
Use AlarmConfig (alarm configuration) to determine alarm message buffer file configuration.
Operators
add, modify, show
Parameters
SERVER
SVC
X
X
Input Parameter
Description
Value/Field Size
Default
[AlarmNumFiles]
Number of alarm files (within the flash file
system) to be used for saving alarm messages.
system) to be used for saving alarm messages.
1, 2, 3, 4.../
1-32
1-32
32
[StartFileNum]
Offset to the starting file for alarm messages in
relation to number of alarm message files
specified by [
relation to number of alarm message files
specified by [
AlarmNumFiles].
0, 1, 2, 3, 4.../
n/a
n/a
0
[NumFilesUsed]
Number of files currently used within the alarm
message buffer (cannot exceed number of files to
store alarms).
message buffer (cannot exceed number of files to
store alarms).
0, 1, 2, 3, 4.../
n/a
n/a
0
[NumAlarmsPerFile]
Number of alarm messages that can be stored per
file within the alarm message buffer. Using a
smaller value results in less file system rewriting
but increases the space wasted per entry, as each
file has fixed overhead.
file within the alarm message buffer. Using a
smaller value results in less file system rewriting
but increases the space wasted per entry, as each
file has fixed overhead.
0, 1, 2, 3, 4.../
n/a
n/a
8
Output Parameter
Description
Default
[Alarm directory]
Name of the directory within the flash file system that contains the alarm
message buffer.
message buffer.
ALARM