2-6   SmartCell 6A000/ZX-250 Reference Manual
  Console Commands
AlarmConfig
Use AlarmConfig (alarm configuration) to determine alarm message buffer file configuration. 
   
Operators
add, modify, show
Parameters
SERVER
SVC
X
X
Input Parameter
Description
Value/Field Size
Default
[AlarmNumFiles]
Number of alarm files (within the flash file 
system) to be used for saving alarm messages.
1, 2, 3, 4.../ 
1-32
32
[StartFileNum]
Offset to the starting file for alarm messages in 
relation to number of alarm message files 
specified by [
AlarmNumFiles].
0, 1, 2, 3, 4.../
n/a
0
[NumFilesUsed]
Number of files currently used within the alarm 
message buffer (cannot exceed number of files to 
store alarms).
0, 1, 2, 3, 4.../
n/a
0
[NumAlarmsPerFile]
Number of alarm messages that can be stored per 
file within the alarm message buffer. Using a 
smaller value results in less file system rewriting 
but increases the space wasted per entry, as each 
file has fixed overhead.
0, 1, 2, 3, 4.../
n/a
8
Output Parameter
Description
Default
[Alarm directory]
Name of the directory within the flash file system that contains the alarm 
message buffer.
ALARM