SmartCell 6A000/ZX-250 Reference Manual   2-7
Console Commands
  
Descriptions
[Alarm Config file]
Name of the file that contains the current configuration of the alarm 
message buffer.
alarmc.db
[Alarm Filename]
Base name of the set of files within the flash file system where alarm 
messages are stored. Alarm message file names are composed of the base 
name and a numeric offset.
zalarm
[Num of alarm files]
Same as [AlarmNumFiles] Input Parameter.
32
[Starting file number]
Same as [StartFileNum] Input Parameter.
0
[Num of used files]
Same as [NumFilesUsed] Input Parameter.
0
[Num of logs per file]
Same as [NumAlarmsPerFile] Input Parameter.
8
Operator
Parameters / Permissions
Description
add 
alarmconfig
[AlarmNumFiles] <numfiles>
[StartFileNum] <startfiles>
[NumFilesUsed] <numfilesused>
[NumAlarmsPerFile] <numalarms>
Administrator
Creates the alarm message buffer file configuration, which 
specifies how alarm messages are saved to the flash file 
system.
Alarm messages are saved in the flash file system and are 
persistent through system reboots. If a configuration file is 
already present, the parameters within the file override any 
alarm message configuration parameters entered through the 
console.
The number of alarm files ranges from 0 to whatever value 
you decide using the [AlarmNumFiles] parameter. The alarm 
file number starts at whatever value you specify using the 
[StartFileNum] parameter. The number of files that contain 
alarm messages is specified by the[NumFilesUsed] 
parameter, which ranges between 0 and whatever value you 
have specified using the [AlarmNumFiles] parameter. The 
maximum number of alarm messages that can be stored is 
[NumAlarmsPerFile] multiplied by [AlarmNumFiles], and is 
limited by the size of the flash file system.
Output Parameter
Description
Default