Period  
Running 
hours  
Service 
Plan 
See 
section 
See 
notes 
below 
table 
Operation 
Daily 
-- -- 3.4 
-- 
Drain 
condensate 
 
-- 
-- 
-- 
-- 
On SF Full-Feature, check dewpoint  
 
 
 
 
 
 
Monthly 
250 
-- 
5.1 
Inspect air filter  
 
 
 
 
 
 
3-monthly  500 
-- -- -- 
Check 
pressure 
drop 
over Atlas Copco filters 
(optional) 
 
 
 
 
 
 
6-monthly  -- -- 5.4 
-- 
Operate 
safety 
valve 
-- -- -- -- 
Clean 
compressor 
-- 
-- 
-- 
-- 
On SF Full-Feature, brush or blow off the finned 
surface of the condenser 
-- 
-- 
-- 
-- 
On SF Full-Feature, clean condensate trap 
internally 
 
 
 
 
 
 
Yearly 
-- -- 5.4 
-- 
Test 
safety 
valve 
-- -- -- -- 
Have 
electrical 
components/shut-down 
switch 
tested 
2500 
5.2 
-- 
Check tension/condition of V-belt(s)  
5000 
5.1 
-- 
Replace air filter 
5000 
-- 
Have ball valve mechanism of condensate trap 
inspected 
5000 
5.2 -- Replace 
V-belt(s) 
 
 
 
 
 
 
2-yearly 
5000  
-- 
Have orbiting scroll bearing greased 
10000 
-- 
Clean compressor element fan and duct.  Clean 
compressor element fins, have seals replaced 
10000 
-- 
Have pin crank bearings greased 
 
 
Notes: 
1. 
Check more frequently if operating in a dusty atmosphere.  Check for cleanness and damage.  
Replace a dirty or damaged filter by a new one. 
2. 
Consult Atlas Copco.